dc axial fans tel: 425-222-5900 800-453-4569 www.mechatronics.com e-mail: sales@mechatronics.com fax: 425-222-5155 cooling simplified model no. rated voltage v operating voltage v current ma speed rpm air volume max. static pressure (h 2 0) sound noise dba weight g m3/min. cfm mm inch ma2506l 5 3 - 6.5 50 6,500 0.03 1.22 1.25 0.05 11.0 8 ma2506m 5 3 - 6.5 60 8,500 0.05 1.65 2.30 0.09 19.0 8 MA2506H 5 3 - 6.5 70 10,500 0.06 2.08 3.37 0.13 25.5 8 (25 x 25 x 6.1 mm) 0.98 x 0.98 x 0.24 inches construction: ul94v-0 pbt impeller & frame bearing option: ball bearing or sleeve connection: awg 30, ul1007 lead wires frame: ribbed protection: thermal options: tachometer output signal air flow (m 3 /min) 4.0 3.0 2.0 1.0 0 0.02 0.04 s tatic pressure - mm of wa ter 0.06 0.08 h m l ma2506 series 0.11 0.01 (?2.8 0.1) 0.98 0.01 (25 0.3) 0.79 0.01 (20.0 0.2) 0.24 0.01 (6.1 0.2) 12.11.14 12.15.14
|